Skip to content

+33 (0)1 48 17 05 19
at your service from 8 AM to 6 PM

A-U-53 - Primer GLASURIT White - primer filler 3L

Technical characteristics A-U-53 Primer-Undercoat

  • Product type : Sandable primer-undercoat
  • Color : White
  • Formulation : Eco Balance with low environmental impact
  • Compatible substrates :
    • Original parts with cataphoresis
    • Old paint
    • GRP / SMC
    • Steel, galvanized steel, aluminum (metal areas to be pre-primed)
  • Mixing ratio : 4 parts A-U-53 / 1 part hardener A-H-200 / 1 part thinner A-R-125, A-R-110, A-R-120 or A-R-130
  • Application viscosity : 18–23 s (DIN 4 at 20°C)
  • Pot life : 60 minutes at 20°C
  • Number of coats : 2
  • Dry film thickness : 50 to 70 µm
  • Flash-off : Until matt between coats (no flash-off before baking)
  • Drying :
    • At 20°C: 3 hours
    • At 60°C: 20 minutes
    • By IR (short waves): 9 minutes
  • Sanding : Dry, orbital, P400 to P600 grit

Properties and advantages

  • Very good sanding ability and excellent finish
  • Good weather and corrosion resistance
  • Compatible with many substrates, including composites and metals
  • Possibility to create greyshades by mixing with A-U-59
  • Eco Balance formulation environmentally friendly
  • Easy application with BP or HVLP spray gun

Recommended applications

  • Surface preparation before painting
  • Fast repair cycles
  • Use on steel, aluminum, galvanized, reinforced plastics (SMC, GRP), old paint, cataphoresis parts
  • Possibility to adjust primer shade with A-U-59

Instructions for use

  • Shake product well before use
  • Mix according to ratio 4:1:1 (product : hardener : thinner)
  • Apply 2 coats with a low pressure gravity feed or HVLP spray gun
  • Recommended air pressure: 2 bar / Nozzle pressure: 0.7 bar
  • Recommended nozzle: 1.6–1.8 mm (BP) or 1.7–1.9 mm (HVLP)
  • Allow to matt between coats
  • Dry as needed: air dry, 60°C oven or IR
  • Dry sanding with P400 to P600 grit

Safety advice

  • For professional use only
  • VOC content: 539 g/l (compliant with Directive 2004/42/IIB.c I – limit 540 g/l)
  • May contain particles < 0.1 µm
  • Wear appropriate PPE: gloves, mask, goggles
  • Work in a ventilated area
  • Follow manufacturer instructions, especially near sensors

Photo non contractuelle